Reports until 12:36, Friday 28 April 2023
H1 CDS (CDS, OpsInfo)
thomas.shaffer@LIGO.ORG - posted 12:36, Friday 28 April 2023 - last comment - 14:50, Thursday 18 May 2023(69140)
Revert models with linked safe.snaps and OBSERVE.snaps

Ryan S, TJ S

Ryan and I looked into all of the symlinks for the safe and observe files as read from the target area for all of the models that are in our SDF Revert scheme. Column 4, and a bit of 5, of this table shows the awkward web that we've created over the years with some safes linked to observes and some to downs, and one the other way around. These are only a small fraction of all of the models, while we haven't gone into all of the others, I imagine the web is equally as tangled. Since we've been locking decently well and seem to have a working system, I don't think it's worth the effort and potential fallout to clean this all up, but I worry that we could definitely confused ourselves further with this inconsistent linking.

All of this stemmed from some diffs in the ISC_EX and ISC_EY (h1syseyiscsdf) that had their observes linked to their safes. I've now unlinked the safe and observe for the for these and made a new link to an observe.snap that was a copy of the safe. I then accepted the differences when we got to low noise.

 

MODEL DCUID userapps_area safe linked to observe linked to
         
alsex 85 als down observe
alsey 95 als down observe
asc 19 asc down observe
ascimc 20 asc down observe
iscex 86 isc down observe
iscey 96 isc down observe
lsc 10 lsc down observe
omc 8 omc down observe
susbs 31 sus down observe
susetmx 88 sus down observe
susetmy 98 sus down observe
sushtts 21 sus safe safe
susifoout 46 sus observe observe
sussqzout 22 sus observe observe
sussqzin 162 sus safe observe
susfc1 161 sus safe observe
susfc2 168 sus safe observe
susitmx 29 sus down observe
susitmy 30 sus down observe
susim 104 sus observe observe
susmc1 34 sus observe observe
susmc2 39 sus down observe
susmc3 35 sus observe observe
susprm 36 sus down observe
suspr2 40 sus down observe
suspr3 37 sus down observe
sussrm 45 sus down observe
sussr2 41 sus observe observe
sussr3 44 sus observe observe
sustmsx 89 sus observe observe
sustmsy 99 sus observe observe
sysexisc 1028 sys safe observe
syseyisc 1031 sys safe observe
Comments related to this report
daniel.sigg@LIGO.ORG - 14:50, Thursday 18 May 2023 (69732)

h1susfc1, h1susfc2 and h1sussqzin are now using identical SDF files with safe pointing to OBSERVE.