Displaying report 1-1 of 1.
Reports until 12:51, Friday 28 April 2023
H1 CAL
ryan.crouch@LIGO.ORG - posted 12:51, Friday 28 April 2023 - last comment - 13:19, Friday 28 April 2023(69156)
PCALY-OFS saturated

PCALY-OFS_PD saturated at 19:37UTC, we toggled it off and back on to fix it at 19:44UTC

Images attached to this report
Comments related to this report
ryan.crouch@LIGO.ORG - 13:07, Friday 28 April 2023 (69158)

The OFS saturated again at 20:03UTC and was toggled off and back on again.

Images attached to this comment
jeffrey.kissel@LIGO.ORG - 13:19, Friday 28 April 2023 (69160)OpsInfo
Suspicious that the issue are the new CAL_AWG_LINES low-frequency PCAL excitations, as defined in LHO:68947, I've reduced the amplitude of all of those PCAL lines by 10% by setting the gain of the H1:CAL-PCALY_DARM bank to be 0.9. We'll run like this for a little bit to see if we like it -- and if we do, I'll edit the gains in the CAL_AWG_LINES guardian.
Displaying report 1-1 of 1.