Fri Apr 28 13:18:55 2023 INFO: Fill completed in 3min 55secs
Bad Fill.
Even with the new trip temps of -100C today's fill was not good. The TCs started around their nominal limits, in fact TC-B was not used for the fill because it started at -74C and nominal was -70C. TC-A quickly exceeded the -100C trip level.
We will give the TCs time to warm up and try again at 15:00 with new settings: trip=-120C and tc-nom=-90C.
Second try was successful.
Fri Apr 28 15:02:04 2023 INFO: Fill completed in 2min 4secs
Gerardo confirmed a good fill via camera. New settings are shown in attachment.
Here is the corrected plot showing the new -120C trip temperature.