Quadratic coupling of frequency noise in DARM

We've known for a while that when we inject laser frequency noise, we see significant downconversion in DARM, together with the expected linear coupling. In particular, when injecting band-limited laser frequency noise in the kHzs region, we see noise in the 100s Hz region getting worse.

Over the past few days I did a few noise and line injections to characterize this coupling. A more detailed analysis will follow, but here are some observations:

The first two plots attached show the effect of injecting noise that mimicks the shape of the 4.3 kHz bump visible in CARM. The first one shows the spectra, the second plot shows the ratio to the quiet time. It's clear that the 100 Hz bump in DARM scales quadratically. It also seems that the downconversion effect is not large enough to be worrisome at this level.

The third plot shows what happens when I injected several lines at high frequency. The red dots shows the lines I injected, while the green Xs shows all the differences in the frequencies. All excess lines in DARM and REFL ERR are marked with a green X, so we see that the coupling is quadratic and does not involve any other line.

The last plot shows that line injections at frequencies outside the 4 - 4.5 kHz band don't produce significant downconversion in DARM.

In a follow up analysis, I plan to model the quadratic coupling from REFL to DARM, and build a noise projection.

Images attached to this report
Comments related to this report
craig.cahillane@LIGO.ORG - 01:20, Tuesday 23 May 2023 (69816)
4.1 kHz is the OMC dither line.
LHO alog 44874

Keita did some nice work in the past on the downconversion from frequency noise near the OMC dither.  At that time we determined it was not limiting DARM.  Is worth doing again.