Front end model timing error, possible Dolphin glitch

We have lost several corner stations front end models in what may be a Dolphin glitch. Caused the lock loss at 16:12PDT.

Images attached to this report
Comments related to this report
erik.vonreis@LIGO.ORG - 17:13, Sunday 30 April 2023 (69190)

h1omc0 was synchronized at the wrong time, see the attached GSD TP screen.  Duotone value is negative.  T0 shows timing was lagging behind by 30 ms.

Output from timing card looked normal.

 

Images attached to this comment
david.barker@LIGO.ORG - 17:22, Sunday 30 April 2023 (69191)

Full set of IOP GDS-TP screens

Images attached to this comment
david.barker@LIGO.ORG - 17:27, Sunday 30 April 2023 (69192)

Jonathan, Erik, Dave, TJ:

We did not see anything useful in the front end logs.


Erik restarted the models on h1omc0, h1susb123, h1sush2a, h1sush34, h1sush56 and h1oaf0.

Note, we did not need to fence front ends from Dolphin and reboot, just model restarts were sufficient.

I cleared all the SWWD watchdogs, no SEI WDs had tripped.

We called TJ who will continue the recovery of the interferometer.

david.barker@LIGO.ORG - 17:28, Sunday 30 April 2023 (69193)

Sun30Apr2023
LOC TIME HOSTNAME     MODEL/REBOOT
16:59:56 h1omc0       h1iopomc0   
17:00:10 h1omc0       h1omc       
17:00:24 h1omc0       h1omcpi     
17:02:29 h1susb123    h1iopsusb123
17:02:34 h1sush2a     h1iopsush2a 
17:02:43 h1susb123    h1susitmy   
17:02:48 h1sush2a     h1susmc1    
17:02:57 h1susb123    h1susbs     
17:03:02 h1sush2a     h1susmc3    
17:03:11 h1susb123    h1susitmx   
17:03:11 h1sush34     h1iopsush34 
17:03:16 h1sush2a     h1susprm    
17:03:25 h1susb123    h1susitmpi  
17:03:25 h1sush34     h1susmc2    
17:03:30 h1sush2a     h1suspr3    
17:03:35 h1sush56     h1iopsush56 
17:03:39 h1sush34     h1suspr2    
17:03:53 h1sush34     h1sussr2    
17:03:55 h1sush56     h1sussrm    
17:04:01 h1oaf0       h1iopoaf0   
17:04:09 h1sush56     h1sussr3    
17:04:15 h1oaf0       h1pemcs     
17:04:23 h1sush56     h1susifoout 
17:04:29 h1oaf0       h1tcscs     
17:04:37 h1sush56     h1sussqzout 
17:04:43 h1oaf0       h1susprocpi 
17:04:57 h1oaf0       h1seiproc   
17:05:11 h1oaf0       h1oaf       
17:05:25 h1oaf0       h1calcs     
17:05:39 h1oaf0       h1susproc   
17:05:54 h1oaf0       h1calinj    
17:06:08 h1oaf0       h1bos       
 

david.barker@LIGO.ORG - 08:38, Monday 01 May 2023 (69203)