Displaying report 1-1 of 1.
Reports until 08:53, Wednesday 03 May 2023
H1 ISC
gabriele.vajente@LIGO.ORG - posted 08:53, Wednesday 03 May 2023 (69279)
Origin of some of the LSC error signal noise

The MICH, PRCL and SRCL in-loop error signals have a fairly flat spectrum above 10 Hz, I assume mostly dominated by sensing noise, and they accumulate all their RMS below 10 Hz, mostly in the region between 0.5 and 5 Hz. I looked at the origin of the "motion" sensed by LSC error signals, by running a coherence analysis (BruCo) on them: MICH, PRCL, SRCL. I used one hour of data and run high resolution FFTs with a bin width of 50 mHz.

PRCL

Most of the RMS is between 2 and 5 Hz. There is coherence with 

Incidentally, there is still a significant 3.47 Hz peak, even with the corrrected offload for PRM. This is mostly coherent with PR2 Y damping

One interesting note: PRCL is highly coherent with LSC-REFL_A_LF_OUT between 4 Hz and 200 Hz: why do we see coherence between PRCL motion and power fluctuations in reflection?
Do we have a PRCL longitudinal offset? Coherence with POP_A_LF is lower, so this might be due to higher order modes. We didn;t have light on the POPAIR diodes, so we cannot see if there is coherence with the sideband powers, that could be another source of the coherence with REFL_A_LF.

In summary, I think that improving PRM and PR2 local damping, and/or improving the angle to length coupling of the M1 stages could reduce the amount of low frequency noise in PRCL. We should also investigate why PR2 damping shows a 3.47 Hz peak.

SRCL

The SRCL loop has lower suppression than PRCL, so there is more RMS being accumulated below 1 Hz or so. There is coherence with

SRCL is also coherent with power fluctuatiion in reflection, for example LSC-REFL_A_RIN, mostly bewteen 10 and 30 Hz, and lower than PRCL. This could be due to SRCL being contaminated by PRCL motion due to a non perfect sensing matrix decoupling.

Improving SR2 P damping and angle to length decoupling of the M1 stage should reduce the SRCL noise below 10 Hz.

MICH

MICH accumulates RMS bewteen 0.1 and 5 Hz. There is coherence with

The 32 Hz peak shows coherence with many signals: ASC-OMC_A_PIT, ASC-AS_A_RF45_I_SUM.
Maybe the most interesting is PEM-CS_ACC_PSL_TABLE2_Z: this is coherent also at the 40.1 Hz peak and at the peaks at 98.3 Hz and 103.6 Hz. Similar coherence with PEM-CS_ACC_PSL_TABLE1_Z

The peaks at 98.3 and 103.6 Hz are coherent with ISI-BS_SUSPOINT_BS_EUL_P and many more ISI-BS signals: is it some real motion of the ISI? This is also coherent around 32.2 Hz, which seems to be a smaller secondary peak near the larger 32.3 Hz peak.

Images attached to this report