victoriaa.xu@LIGO.ORG - posted 16:38, Friday 05 May 2023 (69291)
No-sqz quantum noise at various readout angles, DCPD @ 40mA ~ -12 deg readout angle

With the DARM offset moving to 40mA total DCPD photocurrent (69358), this should correspond to an IFO readout angle of about -12 degrees, given the 1.7mA contrast defect (69361).

Using Craig's calculation of the homodyne / readout angle (65000), as a function of DCPD power level for a 1.7 mW of junk light (68859, 69361),

total_dcpd_light = 20  #mA     # total dcpd mA level
contrast_defect = 1.7  #mA     # this is a recently measured value
darm_offset_power = total_dcpd_light - contrast_defect
homodyne_angle = np.arctan2(np.sqrt(contrast_defect), np.sqrt(darm_offset_power))  #radians
homodyne_angle*180/np.pi    #degrees

Here's the resulting homodyne angle for various DCPD powers:

total dcpd light (mA) homodyne angle (degrees), upper limit
20 -17.0
30 -13.8
40 -11.9

Attached here are some gifs of gwinc-calculated quantum noise for DARM with NO squeezing, rotating through some homodyne angles. The following NO-SQZ GPS times were used:

no_sqz_40mA: 1367358571
no_sqz_40mA_span: 600
no_sqz_20mA: 1367357933
no_sqz_20mA_span: 450