Displaying report 1-1 of 1.
Reports until 00:07, Thursday 04 May 2023
H1 General (CAL, ISC, SUS)
camilla.compton@LIGO.ORG - posted 00:07, Thursday 04 May 2023 (69305)
OPS Evening Shift Summary

TITLE: 05/04 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Locking
SHIFT SUMMARY: Spent most of the eveving with the IFO locked, did some OMC alignment and Louis did Calibration work. Lost lock from CSOFT ring up and IFO is currently locking at AQUIRE_PRMI
LOG: Louis may do more calibration if we get back to NLN.

Lock#1 by Corey (alog69281) to get back to Observing:
Lockloss at 06:02UTC, 6h45m into lock from a CSOFT Pitch ~0.45Hz ring up while calibration measurements were running, see attached control signal. Tagging ISC. The camera servos also saw this and were moving away from zero, plot attached.
Elenna found this afternoon's 21:41 lockloss was the same, alog 69296, and raised the DSOFT, CSOFT gains. What has changed? SRCL offset changed from -165 to -200 at ~21:00 UTC this afternoon (69289).
 
Start Time System Name Location Lazer_Haz Task Time End
22:30 PEM Fil near CER n PEM coil cable check 00:00?
22:30 EE Marc cer n power supply inventory 23:15
23:13 CAL Jeff CR N Calibration 01:13
01:16 COMM Vicky, Camilla CR N OMC Offsets alog 69307 04:00
04:30 CAL Louis Remote N Calibration Suite 06:05
Images attached to this report