Displaying report 1-1 of 1.
Reports until 19:36, Thursday 04 May 2023
H1 CAL
camilla.compton@LIGO.ORG - posted 19:36, Thursday 04 May 2023 (69333)
Calibration Suite taken using pydarm measure at 00:12UTC to 01:49UTC

Louis, Jeff, Camilla

We started the Calibration Suite using 'pydarm measure --run-headless' at 00:12UTC, this runs the sequence: ['bb', 'sens', 'pcal', 'act1x', 'pcal', 'act2x', 'pcal', 'act3x', 'pcal', 'bb']. Took ~1h40.
If the IFO had lost lock with this is still running, it needs to be stopped using CTRL-C and then any remaining open test points cleared using commands >diag >open >awg clear FEC# TP# (e.g. awg clear 125 6). Where FEC# is the computer model number the excitation is on (model with red "E" box) via CDS Overview) and TP# is the test piont number found though CDS overview > model with exc (e.g. H1SUSETMX) > GDS TABLE.

Attached is the sitemap > CAL CS > Calibration Monitor screen ~5 minutes after the first measurement was started. Note that Both CO2s are Annular not central as shown in the screenshot, I'll adjust this medm.

First measurement saved: /ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20230505T000710Z.xml
Last measuremnt saved: /ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20230505T014357Z.xml

'pydarm report' command gave attached report H1_calibration_report_20230505T012609Z.pdf

Images attached to this report
Non-image files attached to this report