TITLE: 05/05 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Lock Acquisition
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 15mph Gusts, 12mph 5min avg
Primary useism: 0.04 μm/s
Secondary useism: 0.13 μm/s
QUICK SUMMARY:
H1's been locked just over 2hrs (after being down ~100min to relock on its own). Range is hovering just below 135Mpc.
I forgot to note we are running in "Automatic" with GRD_IFO and we are NOT in observing. In SDF I do see (2) diffs for SUS damping filters for ITMx & ETMy. (screenshot is attached). Didn't see anything in a quick scan of chat, and will look at alog next.
Also: When I click the "list" feature for the Observation Bit, it comes up with an error: "python3: can't open file '/opt/rtcds/userapps/release/sys/ifo/guardian/IFO_NODE_LIST.py': [Errno 2] No such file or directory"
ACCEPTED the ITMX/ETMy L1_DAMP Filter diffs noted aboe. Which automatically took us to OBSERVING. (I then switched to Managed Observation Bit mode.)