Displaying report 1-1 of 1.
Reports until 07:59, Friday 05 May 2023
LHO General
corey.gray@LIGO.ORG - posted 07:59, Friday 05 May 2023 - last comment - 08:18, Friday 05 May 2023(69339)
Fri Morning Status

TITLE: 05/05 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Lock Acquisition
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 15mph Gusts, 12mph 5min avg
    Primary useism: 0.04 μm/s
    Secondary useism: 0.13 μm/s
QUICK SUMMARY:

H1's been locked just over 2hrs (after being down ~100min to relock on its own).  Range is hovering just below 135Mpc.

Comments related to this report
corey.gray@LIGO.ORG - 08:12, Friday 05 May 2023 (69341)

I forgot to note we are running in "Automatic" with GRD_IFO and we are NOT in observing.  In SDF I do see (2) diffs for SUS damping filters for ITMx & ETMy.  (screenshot is attached).  Didn't see anything in a quick scan of chat, and will look at alog next.

Also:  When I click the "list" feature for the Observation Bit, it comes up with an error:  "python3: can't open file '/opt/rtcds/userapps/release/sys/ifo/guardian/IFO_NODE_LIST.py': [Errno 2] No such file or directory"

Images attached to this comment
corey.gray@LIGO.ORG - 08:18, Friday 05 May 2023 (69342)

ACCEPTED the ITMX/ETMy L1_DAMP Filter diffs noted aboe.  Which automatically took us to OBSERVING.  (I then switched to Managed Observation Bit mode.)

Displaying report 1-1 of 1.