STATE of H1: Calibration
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 3mph Gusts, 1mph 5min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.12 μm/s 
QUICK SUMMARY:

- IFO was locked at NLN for 1:13 (acquired at 13:41 UTC)

- All observe SDFs are cleared, so I flipped the intention bit to OBSERVING @ 14:46 UTC

- CDS/SEI/FOM/DMs all look good

Comments related to this report
camilla.compton@LIGO.ORG - 09:55, Monday 08 May 2023 (69397)OpsInfo

I was mistakenly under the impression that changing the IFO_MODE from Managed (1) to Auto (0) was enough for the IFO to change to OBSERVING (H1:GRD-IFO_OK = 1) once the IFO was READY. As the Guardian Overview shows, this is not enough, I also should have taken the Intention bit (H1:GRD-IFO_REQUEST) to OBSERVE for this to work. I didn't do that when I left Friday night as we were doing a calibration suite (69362) but I could have done as the IFO_READY flag would not have actually taken us to Observing until calibration was finished.

Images attached to this comment