30 minutes of no SQZ time this Morning

Austin and I took SQZ_MANAGER from FREQ_DEP_SQZ to SQZ_READY_IFO for 30 minutes of no-squeezing time 16:02UTC to 16:34UTC

The IFO had been locked for 18 hours. Range dropped from 133MPc down to 113MPc. Both of these range values seem lower than earlier in the week but there was a lot of changes on Friday (69365). 

Images attached to this report
Comments related to this report
victoriaa.xu@LIGO.ORG - 13:43, Monday 08 May 2023 (69417)

Just checking -- and it seems not a huge difference in squeezing levels over ~10 min with squeezer ASC's ON/OFF. Low frequency differences likely just due to noise technical noise drifts. GPS times:
FDS FC+SQZ ASC OFF (blue): 1367613320 + 10 min
FDS FC+SQZ ASC ON (black) 1367612238 + 15 min