J. Kissel
In hopes that we would have a few thermalization periods measured over the weekend in our new SRCL offset at -265 (LHO:69359) and our new DARM offset set such that there's 40 mA total of photocurrent on the DCPDs (H1:OMC-READOUT_X0_OFFSET ~= 9.7, see LHO:69358), I went to run Evan's thermalization script (LHO:69301) ... but came up with noise only for the PCALY 8.925, 11.575, 15.275, 24.5 Hz lines driven by CAL_AWG_LINES.
Sadly, it looks like the PCAL model's test points (FEC DCUID 125) were cleared on 2023-05-06 15:57 UTC, or (Saturday morning at 08:57 PDT), and they've not been restored. I think this might have resulted in some confusion regarding instructions on how to run calibration measurements headlessly, in that the test points were cleared even though the headless measurement succeeded normally without the IFO losing lock. (LHO:69396).
I've edited the wiki page instructions to be more clear.