Displaying report 1-1 of 1.
Reports until 16:47, Monday 08 May 2023
H1 ISC
elenna.capote@LIGO.ORG - posted 16:47, Monday 08 May 2023 (69420)
Changed soft loop gains (again)

We narrowly avoided disaster today when CSOFT P again rung up at 0.45 Hz. I was able to drop the gain and save the lock. This was in the midst of many SRCL offset changes and measurements. Once we settle on a SRCL offset, I will take another sensing matrix measurement and check if the input matrix needs updating again. I have updated the soft loop gains in the guardian again.

When we get back to NLN, there will be SDFs that need to be accepted in the ASC model.

Displaying report 1-1 of 1.