Displaying report 1-1 of 1.
Reports until 00:03, Saturday 06 May 2023
H1 General (CAL, SQZ)
camilla.compton@LIGO.ORG - posted 00:03, Saturday 06 May 2023 - last comment - 11:29, Wednesday 10 May 2023(69365)
OPS Evening Shift Summary
TITLE: 05/06 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Calibration
SHIFT SUMMARY:  Lots of IFO changes today, locking was a little tricky, we had 2 hours in Observing and now Losuis is taking some Calibration measurements,
LOG:
 
Lots of changes during the day today, mainly:

LOCK#1

After the IFO was locked 5h13, we lost lock at 01:06UTC from ASC changes.

Elenna loaded a new MICH filter after the lockloss.

LOCK #2

Had a tough time relocking (later we noticed it seemed like CHECK_MICH_FRINGES moved the BS the wrong way at around 2:00UTC). This BS move made the DIFF beat note too low (-30) for LOCKING_ALS. I attempted an initial alignment. Couldn't get XAMR IR locked eso exited from initial alignment. Reverted BS pointing to before CHECK_MICH_FRINGES and touched PRM during ACQUIRE PRMI. Finally locked again. Inputting 76W at 03:45 UTC and at NLN at 04:20UTC. Delay due to OMC_WHITENING limited needed to be changed, alog69371.

Observing at 04:35UTC. SDFs accepted:

At 05:59UTC we had the 10.4Hz PI ring up (PI # 24), I was notified via verbalalarms and it and was successfully damped by the PI_DAMPING guardian, no intervention needed, Vicky's alog 69318 changes were good. See attached plot.

Start Time System Name Location Lazer_Haz Task Time End
21:39 COMM Jennie.Naoki.Vicky CR N

DARM spring and SCRL offsets, SQZ, FC alignments.

01:08
03:22 SQZ Naoki CR N Injecting SQZ during locking 04:22
6:45 SQZ Camilla CR N SQZ angle adjustments 6:52
6:55 CAL Louis Remote N Calibration eta 7:30
Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 11:22, Monday 08 May 2023 (69405)

Notes on struggle Austin (69378) and I had for ACQUIRE_XARM_IR (state 11 of ALIGN_IFO) during INITIAL_ALIGNMENT. ALIGN_IFO is checking for LSC-XARM_FM_TRIG_MON to trigger and then it will turn off MCL gain and continue, since Friday evening this has triggered but not hed and ALIGN_IFO hasn't moved forward.

Plot attached comparing on the left a successful Initial alignment 2023/05/05 04:15 UTC verus on the right the failed alignment 2023/05/06 02:00 UTC. Light levels on the H1:ASC-X_TR_A_SUM_OUT16 while unlocked didn't get above their zero values.

Images attached to this comment
camilla.compton@LIGO.ORG - 11:29, Wednesday 10 May 2023 (69477)

Attaching plot for time (2023/05/06 01:43 UTC) that CHECK_MICH_FRINGES reduced DIFF beatnote from -24 to -30. Not sure if this is expected.

Images attached to this comment
Displaying report 1-1 of 1.