Reports until 02:01, Thursday 11 May 2023
H1 General
anthony.sanchez@LIGO.ORG - posted 02:01, Thursday 11 May 2023 - last comment - 13:54, Wednesday 01 November 2023(69497)
Wednesday Eve ops End Shift report

TITLE: 05/11 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Aligning
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 7mph Gusts, 6mph 5min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.25 μm/s
QUICK SUMMARY:
IFO'S Current Status: unlocked and misaligned.
 

Hear we go: 
21 seconds into my shift there was a lockloss
https://ldas-jobs.ligo-wa.caltech.edu/~lockloss/index.cgi?event=1367794839

ITMY Mode 8 Violin is ringing up again. Changed the gain from -0.4 to 0 again, and I'll be watching it.
 
00:32 UTC Lockloss for an unknown reason
https://ldas-jobs.ligo-wa.caltech.edu/~lockloss/index.cgi?event=1367800386

Dolphin error cause a lockloss and the SUS models needed to be restarted. 
https://ldas-jobs.ligo-wa.caltech.edu/~lockloss/index.cgi?event=1367803504

Everything on OPS Overview was Red and all the watch dogs had been tripped.
I Reset all suspension WDs, took all suspensions to safe, then reset all ISI's WDS, then Reset ALL HEPI WDs.

Finally got every thing back into what I thought was working order but relized that I don't have any light on the ALSX and ALSY cams. 
I am now running the Dither scripts noted in alog 62024 for both X and Y arm.  
AS Air looks oddly center on the AS Air cam instead of it's natrual state of top right.
The dither scripts took AS air cam back to what I would consider it's natural state in the top left.

I now have light on both arms! Yay!
Me and Increase flashes became best of buds while we both tryed to get X arm above 0.50. 

ETMX TMSX ITMX PRM and PRM3 all got moved whle trying to increase flashes.

I wasted a hour an hour trying to find information on adjusting the OPLEVS and never ended up finding them let alone touching them.  
I eventually manage to get a good ALS X & Y alignment after time machining back to look at a number of sliders on the IFO_ALign screen and re-adjusting PRM and PR3. 

Started an INIT_ALIGN and got stuck in ACQUIRE_XARM_IR, Then spend an hour or 2 searching through the troubleshooting Docs & alogs to try and find a way to get past this: 
2023-05-11_07:33:31.707994Z ALIGN_IFO [ACQUIRE_XARM_IR.main] ezca: H1:LSC-XARM => ON: INPUT
2023-05-11_07:33:31.709570Z ALIGN_IFO [ACQUIRE_XARM_IR.main] timer['pause'] = 3
2023-05-11_07:33:31.785294Z ALIGN_IFO [ACQUIRE_XARM_IR.run] timer['pause'] = 0.5

I then tried to cancel out of INIT_ALIGN because I remember I heard there were some problems with getting through INIT_ALIGN a few days ago. Then my plan was to try and have ISC_LOCK's FIND_IR stage in the Locking sequece get me past that spot in the Alignment.
Would you be Surprised if I said that IR was not found? I had to touch both up COMM and DIFF. 

I then got stuck in Check Mitch Fringes. And bumped the BS around until it got stuck in Aquire PRMI Again. The Troubleshooting document mentions MICH_Dark_LOCK but not Mitch fringes. 
I then Spend an hour or 2 looking for information on that.

I then tried to restore ALL Sliders back to 24 hours ago when we were locked.
and tried the above process over again.

Then I tried restoring ALL Sliders back to a time where we were unlocked but had Good ASL X&Y flashes right before a lock and tried the process over again.

I believe I am missing some important nuggets of knowlege on how to get IFO locked from a misaligned state.
Things I wanted to do But couldn't figure out how: Check OSEMS and OPLEVS. 


 

Images attached to this report
Comments related to this report
anthony.sanchez@LIGO.ORG - 13:54, Wednesday 01 November 2023 (73914)

Potential Solution to this because I found myself in this situation again last night see https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=73891 with Jenne's notes.
If you find your self stuck in this postition again, specifically when PR3 has been drifting due to temperature changes or something.

Note the COMM beat note, this may be a clue as to what is going wrong. If the magnitude of the COMM beat note is too low below ~ -16 , Follow the instructions in Jenne's comment on 73891 linked above.
OR
First: Go back to green arms locked and touch PR3 while watching the Comm Beat note aiming for (-8 to -4) depending on conditions. Beawre that the Diff beatnote may change for worse and we must balance this with the optimization of the comm beat note.
The go back to initial alignment. And if that doesn't work then follow Jenne's comment on 73891  .

Good luck