Reports until 11:22, Thursday 11 May 2023
H1 CAL (CDS, DetChar, OpsInfo)
jeffrey.kissel@LIGO.ORG - posted 11:22, Thursday 11 May 2023 (69514)
PCAL OFS Loop Reset
J. Kissel

I blame the dolphin crash last night LHO:69492, but I saw the that PCALX RX PD showed some excess noise up on the front wall FOM so I've open and re-closed both PCALX and PCALY optical follower servo (OFS) enable switch.

FIXED IT.

PCALs functional again as of May 11 2023 18:17 UTC.