jeffrey.kissel@LIGO.ORG - posted 13:13, Thursday 11 May 2023 (69517)
OM2 alignment was way off -- Adjusted Alignment
J. Kissel, T. Shaffer

As a continued parts of the recovery, even after Tony reset the alignment sliders for all suspensions to a time prior to the dolphin crash, we continued struggling to align the SRC. Trending the OSEMs, we found that OM2 had particularly different align than the beginnings the last successful lock acquisition attempt. OM3 also showed a bit of drift due to the temperature excursion. 

So, we've now restored the alignment to the OSEM values to 2023-05-10 23:11 UTC, and initial alignment seems to be going much better now.

(The attached trend shows pitch on the left, and yaw on the right, for columns of OM1, OM2, and OM3. The horizontal cursor Y1 is set to the 2023-05-10 23:11 UTC values in each, and the Y2 cursor is set to what the values were just before this fix.)

FIXED IT.