Displaying report 1-1 of 1.
Reports until 12:57, Friday 12 May 2023
H1 SUS (SUS)
rahul.kumar@LIGO.ORG - posted 12:57, Friday 12 May 2023 (69544)
New settings for damping ITMY mode08 (phase and gain change)

ITMY mode08 has been troubling us for the past few days as the nominal settings has stopped working. I have found a new setting which looks to be working (see screenshot attached below) - with a new phase and gain. I need to test this out for a couple of locks before making the changes in lscparams and in the SDF. The new filters and gain are shown below,

New settings: FM1 FM3 FM10,  Gain = 0.01

Old settings: FM1 FM2 FM10, Gain = -0.04

Images attached to this report
Displaying report 1-1 of 1.