LOG: Leaving the IFO in observing, has been locked  2h30. Elenna plans to take the IFO briefly out of Observing ~1am to take LSC FF injections.

03:07 UTC Lockloss 1368241693

Adrian was running an injection on H1:PEM-CS_GDS_6_EXC, it came up on the CDS model GDS table but not on the OPS > TEST POINTS screen, see attached. Tagging CDS.

Start Time System Name Location Lazer_Haz Task Time End
22:53 VAC Jordan & Gerardo Mid X N Dropping off parts 23:15
23:03 PEM Robert, Anamaria EY N EY Shaker move 23:50
23:03 COMM Elenna CR N Mich OLG 23:24
23:24 PCAL Tony PCAL Lab local PCAL (stepping past LVEA change room for laptop) 23:46
23:57 PEM Robert, Adrian LVEA N East Bay PEM speaker set up 00:13
02:14 PEM PEM Team CR N EY shaker injections with ETMY A2L moves 03:07
03:07 IFO       Lockloss from EQ  
03:21 PEM Adrian CR N PEM Magnetic Injections while locking/first minutes of NLN 05:21
06:19 SQZ Camilla CR N SQZ angle adjustments 7:15
Images attached to this report