Dark offset script ran

Jeff brought up a good point that after the LSC, ASC, and OMC rack work today, it would be a good idea to run the dark offset script to get new offsets. These dark offsets are basically offsetting electrics noise that can change as the state of the electronics changes.

Corey followed these usual steps:

  1. Bring IMC_LOCK to OFFLINE
  2. Misalign the ITMs
  3. Shutter ALSs
  4. Run /opt/rtcds/userapps/release/isc/h1/scripts/dark_offsets/dark_offsets_exe.py

I've attached screenshots of the safe SDF changes, I'll work on the observes when we get up.