Displaying report 1-1 of 1.
Reports until 00:03, Wednesday 17 May 2023
H1 General (CAL)
austin.jennings@LIGO.ORG - posted 00:03, Wednesday 17 May 2023 - last comment - 08:29, Wednesday 17 May 2023(69675)
Tuesday Eve Shift Summary

TITLE: 05/16 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Commissioning
SHIFT SUMMARY:

Main Notes:

- PEM injections/SQZ work early on in the day

- Couple locklosses - both due to unknown reasons

- Currently sitting at MAX_POWER on the way back to NLN, I have set the OBSERVING bit to AUTO so it should catch when the SDFs are cleared

- Lock #1:

- LOCKLOSS @ 23:31 UTC - reason currently unknown

- Lock #2:

- Acquired NLN @ 00:52, In OBSERVING @ 4:02

- SQZ/PEM injections ongoing

- When trying to transition to OBSERVE, I ran into some SDF diffs for CALEY - accepting, Tagging CAL 

- LOCKLOSS @ 05:38 - DCPD saturation, reason unknown

- Lock #3:

- Automation failed 3x trying to ACQUIRE_PRMI, would catch for a bit then fail when the ASC engages, intervened next time around and moved PRM ~17 microradians in Y (353.3 --> 336.6) which allowed it to catch

- INCREASE FLASHES on X seems to work good, but sometimes fails to offload when flashes look good enough to catch
LOG:

Start Time System Name Location Lazer_Haz Task Time End
02:30 PCAL Tony PCAL Lab Y (LOCAL) Measurements 02:45
01:15 GAINZ Camilla + gang X arm N Brisk 10k 02:12
Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 08:29, Wednesday 17 May 2023 (69686)CAL, OpsInfo
These PCALY SDF differences are understood (and it didn't matter whether they were accepted or reverted) -- before I left last night, I was setting up parameters for getting thermalization lines at lower frequency, as desired as a result of LHO:69593. When I left, I restored the amplitude of these oscillators to zero, so no new excitations / calibration lines went in to the detector. 

Thanks for aLOGging!
Displaying report 1-1 of 1.