Displaying report 1-1 of 1.
Reports until 00:01, Wednesday 17 May 2023
H1 SQZ
victoriaa.xu@LIGO.ORG - posted 00:01, Wednesday 17 May 2023 (69679)
SQZ catchup from computer restarts, going to slightly higher NLG (about 4 to 9)

Catching up on issues since computer restarts, lvea temp drifts, and bringing SHG powers back to normal. IFO was lightly thermalizing its last 5kW in the course of these measurements, taken ~2.5-3 hours after reaching NLN. I think increasing generated SQZ levels from about 9 dB --> 14dB (NLG 4-->9) increased high-frequency squeezing by ~0.3-0.6dB.

Lockloss a while after. While IFO was down, I re-aligned fiber polarizations given the recent LVEA temp drifts:
   -  opo pump fiber (OPO GRD 'LOCKED_CLF_DUAL_NO_ISS', minimize in-vac rejected power H1:SQZ-SHG_FIBR_REJECTED_DC_POWER)
   -  clf fiber (CLF GRD 'DOWN', maximize CLF_REFL_LF_OUT_DQ)
   -  fcgs fiber (doesn't matter GRD state, I minimized in-vac rejected power H1:SQZ-FC_FIBR_REJECTED_DC_POWER. This one was pretty close.)

Maybe sometime we can check the SQZ ASC gain / time constant and make sure it makes sense, since its outputs seem to move a lot very quickly? Also, since IFO was still thermalizing, if we have no-sqz time with a very thermalized IFO, it might be worth re-setting the AS42 no-sqz offsets again then.