Reports until 10:05, Wednesday 17 May 2023
H1 SUS (SUS)
rahul.kumar@LIGO.ORG - posted 10:05, Wednesday 17 May 2023 (69692)
Violin mode IY07 phase change

I have found a new setting for ITMY mode 07 since the nominal settings was making it grow (past couple of locks). Given below are the settings which works - see ndscope attached  (old settings shows the mode is growing and the new one drops quickly) below,

New: FM1+FM10, Gain 0.1

Old: FM1+FM2+FM10, Gain 0.1

I have made the above changes in lscparams and accepted the changes in SDF.OBSERVE file.

Images attached to this report