mark.barton@LIGO.ORG - posted 12:14, Wednesday 03 July 2013 (6976)
More SUS screen cleanup

Further to SUS screen cleanup in alogs 6926 and 6893, I went through the whole $(USERAPPS)/sus/common/medm/quad directory, checking that all linked screens were supplied with a full set of arguments via the argument macro files. I opened each file in gedit and searched for the "args=" lines corresponding to the Arguments fields of the Related Display Data dialog in the MEDM editor. Because nearly all the links were between generic screens but for the same optic I used the following args string:

args="%(read $(USERAPPS)/sus/common/medm/sus$(optic)_overview_macro.txt),USERAPPS=$(USERAPPS),SITE=$(SITE),site=$(site),IFO=$(IFO),ifo=$(ifo)"

Everything worked, so I committed the mods. As time permits I'll do the same for all the other suspension types.

Files updated today:

SUS_CUST_MAIN_MENU.adl - did token cleanup because probably not used. Made H2 and L1 specific calls generic but didn't remove FMx/FMy stuff.

SUS_CUST_QUAD_DACKILL.adl - 2 args lines updated.

SUS_CUST_QUAD_L1_CENTERING.adl - 6 args lines updated.

SUS_CUST_QUAD_L1_WD.adl - 6 args lines updated.

SUS_CUST_QUAD_L2_CENTERING.adl - 6 args lines updated.

SUS_CUST_QUAD_L2_WD.adl - 3 args lines updated.

SUS_CUST_QUAD_L3_OPLEV.adl - 3 args lines updated.

SUS_CUST_QUAD_M0_CENTERING.adl - 8 args lines updated.

SUS_CUST_QUAD_M0_WD.adl -  4 args lines updated.

SUS_CUST_QUAD_R0_WD.adl - 4 args lines updated.

SUS_CUST_QUAD_R0.adl - 14 args lines updated.

SUS_CUST_QUAD_R0_CENTERING.adl - 8 args lines updated.

FIles modified previously (alogs 6926 and 6893):

SUS_CUST_QUAD_OVERVIEW.adl - 64 args lines and 6 name lines updated.

SUS_AUX_QUAD_OVERVIEW.adl - 1 args line and 1 name line updated.

No action required: SUS_CUST_QUAD_IPC.adl, SUS_CUST_QUAD_ADC_MONITOR.adl, SUS_CUST_QUAD_L1_CENTERING_??ZOOM.adl, SUS_CUST_QUAD_L1_COILOUTF.adl, SUS_CUST_QUAD_L1_DAMP.adl, SUS_CUST_QUAD_L1_EUL2OSEM.adl, SUS_CUST_QUAD_L1_DRIVEALIGN.adl, SUS_CUST_QUAD_L1_LOCK.adl, SUS_CUST_QUAD_L1_OSEM2EUL.adl, SUS_CUST_QUAD_L1_OSEMINF.adl, SUS_CUST_QUAD_L1_SENSALIGN.adl, SUS_CUST_QUAD_L1_TEST.adl, SUS_CUST_QUAD_L1_WD_ACT_BANDLIM.adl, SUS_CUST_QUAD_L1_WD_OSEMAC_BANDLIM.adl, SUS_CUST_QUAD_L1_WD_OSEMDC_BANDLIM.adl, SUS_CUST_QUAD_L2_OSEM_ALIGN_??ZOOM.adl, SUS_CUST_QUAD_L2_COILOUTF.adl, SUS_CUST_QUAD_L2_DAMP.adl, SUS_CUST_QUAD_L1_DRIVEALIGN.adl, SUS_CUST_QUAD_L2_EUL2OSEM.adl, SUS_CUST_QUAD_L2_LOCK.adl, SUS_CUST_QUAD_L2_OSEM2EUL.adl, SUS_CUST_QUAD_L2_OSEMINF.adl, SUS_CUST_QUAD_L2_SENSALIGN.adl, SUS_CUST_QUAD_L2_TEST.adl, SUS_CUST_QUAD_L2_WD_ACT_BANDLIM.adl, SUS_CUST_QUAD_L1_WD_OSEMAC_BANDLIM.adl, SUS_CUST_QUAD_L2_WD_OSEMDC_BANDLIM.adl, SUS_CUST_QUAD_L3_DRIVEALIGN.adl, SUS_CUST_QUAD_L3_ESDOUTF.adl, SUS_CUST_QUAD_L3_EUL2ESD.adl, SUS_CUST_QUAD_L3_ISCINF.adl, SUS_CUST_QUAD_L3_LOCK.adl, SUS_CUST_QUAD_L3_OPLEV_MTRX.adl, SUS_CUST_QUAD_L3_OPLEV_SEGS.adl, SUS_CUST_QUAD_L3_TEST.adl, SUS_CUST_QUAD_L3_WD.adl, SUS_CUST_QUAD_M0_CART2EUL.adl, SUS_CUST_QUAD_M0_OSEM_ALIGN_??ZOOM.adl, SUS_CUST_QUAD_M0_COILOUTF.adl, SUS_CUST_QUAD_M0_DAMP.adl, SUS_CUST_QUAD_M0_DCDRIVECAL.adl, SUS_CUST_QUAD_M0_DRIVEALIGN.adl, SUS_CUST_QUAD_M0_EUL2CART.adl, SUS_CUST_QUAD_M0_EUL2OSEM.adl, SUS_CUST_QUAD_M0_ISIINF.adl, SUS_CUST_QUAD_M0_LOCK.adl, SUS_CUST_QUAD_M0_OFFLOAD.adl, SUS_CUST_QUAD_M0_OPTICALIGN.adl, SUS_CUST_QUAD_M0_OSEM2EUL.adl, SUS_CUST_QUAD_M0_OSEMINF.adl, SUS_CUST_QUAD_M0_SENSALIGN.adl, SUS_CUST_QUAD_M0_TEST.adl, SUS_CUST_QUAD_M0_WD_ACT_BANDLIM.adl, SUS_CUST_QUAD_M0_WD_OSEMAC_BANDLIM.adl, SUS_CUST_QUAD_M0_WD_OSEMDC_BANDLIM.adl, SUS_CUST_QUAD_ODC.adl, SUS_CUST_QUAD_R0_OSEM_ALIGN_??ZOOM.adl, SUS_CUST_QUAD_R0_COILOUTF.adl, SUS_CUST_QUAD_R0_DCDRIVECAL.adl, SUS_CUST_QUAD_R0_DAMP.adl, SUS_CUST_QUAD_R0_DRIVEALIGN.adl, SUS_CUST_QUAD_R0_EUL2OSEM.adl, SUS_CUST_QUAD_R0_OPTICALIGN.adl, SUS_CUST_QUAD_R0_OSEM2EUL.adl, SUS_CUST_QUAD_R0_OSEMINF.adl, SUS_CUST_QUAD_R0_SENSALIGN.adl, SUS_CUST_QUAD_R0_TEST.adl, SUS_CUST_QUAD_R0_WD_ACT_BANDLIM.adl, SUS_CUST_QUAD_R0_WD_OSEMAC_BANDLIM.adl, SUS_CUST_QUAD_R0_WD_OSEMDC_BANDLIM.adl