Reports until 01:51, Tuesday 23 May 2023
H1 General
corey.gray@LIGO.ORG - posted 01:51, Tuesday 23 May 2023 (69810)
H1 Recovery Status

With the Dolphin Crash at around 8pmPT, for H1, it primarily affected the Corner Station's SUS & SEI (but not every chamber).  After Dave restored the CDS side of things, we worked on bringing back the SUS and then the SEI (with Rahul and Jim).  Some notes:

ALIGNMENT #1:

INIT_ALIGN Errors:

INPUT ALIGN:

Once INPUT ALIGN was completed, I continued with ALIGN_IFO to complet the Initial Alignment (I did not use INIT_ALIGN because it wasn't working for me---due to the ERRORs).

LOCKING:

Since I was worried the alignment was not run correctly due to the INIT ALIGN error, I decided to run another alignment letting ALIGN IFO use INIT ALIGN.

ALIGNMENT #2:

Mostly a straightforward alignment, BUT for SRC ALIGN:  There were SRM saturations via Verbal---not a good a sign.  These saturations would continue even after offloading.  So something had to be amiss---I must have missed something from the crash.

Since it was almost midinght, I went for another lock, and sadly, H1 made it through DRMI, but it continued to have SRM saturations and at the lockloss the HAM4 & HAM5 ISIs tripped again.  This is when I handed off to Ryan.

Additional NOTE:

Here Is the INIT_ALIGN error:

2023-05-23_06:26:02.156247Z INIT_ALIGN [LOCKING_GREEN_ARMS.main] timer['y_locked_but_no_wfs'] = 0
2023-05-23_06:27:02.154391Z INIT_ALIGN [LOCKING_GREEN_ARMS.run] timer['x_not_locked'] done
2023-05-23_06:27:02.156131Z INIT_ALIGN [LOCKING_GREEN_ARMS.run] timer['y_not_locked'] done
2023-05-23_06:28:41.334397Z INIT_ALIGN W: Traceback (most recent call last):
2023-05-23_06:28:41.334397Z   File "/usr/lib/python3/dist-packages/guardian/worker.py", line 494, in run
2023-05-23_06:28:41.334397Z     retval = statefunc()
2023-05-23_06:28:41.334397Z   File "/usr/lib/python3/dist-packages/guardian/state.py", line 246, in __call__
2023-05-23_06:28:41.334397Z     main_return = self.func.__call__(state_obj, *args, **kwargs)
2023-05-23_06:28:41.334397Z   File "/usr/lib/python3/dist-packages/guardian/state.py", line 246, in __call__
2023-05-23_06:28:41.334397Z     main_return = self.func.__call__(state_obj, *args, **kwargs)
2023-05-23_06:28:41.334397Z   File "/opt/rtcds/userapps/release/isc/h1/guardian/INIT_ALIGN.py", line 130, in run
2023-05-23_06:28:41.334397Z     nodes[f'ALS_{xy}ARM'] = 'INITIAL_ALIGNMENT_OFFLOADED'
2023-05-23_06:28:41.334397Z NameError: name 'xy' is not defined
2023-05-23_06:28:41.335859Z INIT_ALIGN [LOCKING_GREEN_ARMS.run] USERMSG 0: USER CODE ERROR (see log)
2023-05-23_06:28:41.388535Z INIT_ALIGN ERROR in state LOCKING_GREEN_ARMS: see log for more info (LOAD to reset)
2023-05-23_06:28:54.822757Z INIT_ALIGN LOAD REQUEST
2023-05-23_06:28:54.827322Z INIT_ALIGN RELOAD requested.  reloading system data...
2023-05-23_06:28:54.872241Z INIT_ALIGN module path: /opt/rtcds/userapps/release/isc/h1/guardian/INIT_ALIGN.py
2023-05-23_06:28:54.872241Z INIT_ALIGN user code: /opt/rtcds/userapps/release/isc/h1/guardian/ISC_library.py
2023-05-23_06:28:54.872552Z INIT_ALIGN user code: /opt/rtcds/userapps/release/isc/h1/guardian/lscparams.py
2023-05-23_06:28:54.872552Z INIT_ALIGN user code: /opt/rtcds/userapps/release/sys/h1/guardian/timeout_utils.py
2023-05-23_06:28:55.722360Z INIT_ALIGN RELOAD complete
2023-05-23_06:28:55.723769Z INIT_ALIGN W: RELOADING @ LOCKING_GREEN_ARMS.run