J. Kissel, T. Shaffer

In order to aide recovery later today post round two of changing out the power supplies for the ISC racks (WP 11193, LHO:69652, LHO:69631), TJ and I offloaded the MC WFS to their suspension's alignment and input PZT sliders (while the IMC is locked, use IMC_LOCK guardian, request MCWFS_OFFLOADED).
Then, to make sure it sticks across computer reboots, we accepted them in each computer's safe.snap SDF file. 
    - Because alignment sliders are not monitored in SUS SDF systems, for the IMC SUS, MC1, MC2, and MC3, this means changing the SDF view to FULL_TABLE, and accepting OPTICALIGN*OFFSET values,
    - for the input PZTs, which live in the h1ascimc front-end model, we merely accepted them in the SETTINGS_DIFFS list, because these *are* monitored.

Neither SUS nor PZTs offset changes were that large, but it'll help.