Displaying report 1-1 of 1.
Reports until 17:43, Tuesday 23 May 2023
H1 ISC (ISC, OpsInfo)
jeffrey.kissel@LIGO.ORG - posted 17:43, Tuesday 23 May 2023 - last comment - 17:52, Tuesday 23 May 2023(69864)
Lockloss from Reverting MICH and SRCL FF Filters and Tramps
J. Kissel, C. Gray

That lock loss from NOMINAL_LOW_NOISE at 2023-05-24 00:33 UTC was me. 

I was running through the SDF system looking to accept or revert changes to get ready for observing, saw that there were filter differences and tramp differences in the in-loop MICH and SRCL FF in the LSC model, and we thought were Corey was starting the FF test discussed in LHO:69862 a little too early. As soon as I hit "revert" we lost lock. I don't have a screenshot of the DIFFs, but Corey thinks that these filters DIFFs were a result of him accepting the "newer" "5-20-23" filters provided last night just to get us to obseve (see brief mention of the acceptance in LHO:69801, and some discussion of the filters in LHO:69785). We think these showed up as a DIFF tonight because the ISC_LOCK guardian had reset it to the "normal" filters "4-15-23". Or something. 

But clearly switching these filters at the speed of a button click does not make the IFO happy.

Comments related to this report
jeffrey.kissel@LIGO.ORG - 17:52, Tuesday 23 May 2023 (69865)OpsInfo
Silver lining -- we've recovered NOMINAL_LOW_NOISE at 2023-05-24 00:18 UTC after a long 24 hours of dolphin crashes...
Displaying report 1-1 of 1.