Reports until 08:23, Wednesday 24 May 2023
LHO General
thomas.shaffer@LIGO.ORG - posted 08:23, Wednesday 24 May 2023 (69882)
Ops Day Shift Start

TITLE: 05/24 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Lock Acquisition
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 5mph Gusts, 3mph 5min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.10 μm/s
QUICK SUMMARY: Walked in with Ryan trying to get DRMI to lock. It looked liked something in the SRC was off so we reran the SRC alignment part of initial alignment and it wouldn't lock. I moved SRM in pitch by 133 urad and yaw by ~75urad and then it locked and finished offloading. DRMI then locked without issue and we are moving forward with locking.