Reports until 14:44, Friday 26 May 2023
H1 ISC
camilla.compton@LIGO.ORG - posted 14:44, Friday 26 May 2023 - last comment - 17:48, Friday 26 May 2023(69930)
PR Suspension alignment over last weeks.

AM control room team: RyanS, TJ, Sheila, Keita, Vicky...

Trended alignment of PRM, PR2, PR3 over last 2 weeks. It is unusual to change PR3 alignment but recently we've had to touching PR3 to get PRMI locked (69751, 69917, 69924, 69903): 3urad in last 2 weeks. Top right pink trace attached.

Sheila noted that the the POPAIR and ALS (green) beat notes were reducing and then being brought back by PR3 moves (1st t-cursor). ALS beatnote realigning on ISCT1 in last 2 days (2nd t cursor, alogs 69897, 69897) brought back green comm/diff beat notes but not POPAIR.  Sheila/Keita/Vicky noted this suggests something common on the green + IR path is drifting.

For newer information including HAM yaw motion, see TJ's alog 69924 .

Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 17:48, Friday 26 May 2023 (69936)
The problem was that the HAM-ISIs were all drifting off in Yaw (RZ) slowly, but surely, for weeks -- see LHO:69934.