Reports until 00:20, Saturday 27 May 2023
H1 General (OpsInfo)
anthony.sanchez@LIGO.ORG - posted 00:20, Saturday 27 May 2023 (69960)
Friday Eve Ops Shift End

TITLE: 05/27 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 126Mpc
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 3mph Gusts, 2mph 5min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.07 μm/s
QUICK SUMMARY:

Richard told me I need to Keep and eye on LVEA Temps because A fan was shut off. we expect to see temps fall.

The temp in the Y Ebay seemed warm at 26.1 C. So I trended back the last 10 days and noticed that H1:PEM-Y_EBAY_RACK1_TEMPERATURE reached over 45 C in the Ebay. I'm not sure if that s accurate or not but it seems like something to make a note of.

H1:PEM-Y_EBAY_RACK1_TEMPERATURE seems too high when I compare it to H1:PEM-X_EBAY_RACK1_TEMPERATURE which hasn't changed more than a degree in the last 10 days. My Previous alog tags FMCS.

SR3 Returned to Pit 437.1, yaw -149.1 which is what they were April 13 at 3:00 UTC.
2:40 UTC PI 29  ring up, the Filter cycled through and caught it before it grew so large to cause a lock loss.

LockLoss 5:27 UTC lockloss reason currently unknown
https://ldas-jobs.ligo-wa.caltech.edu/~lockloss/index.cgi?event=1369200467

Relocking without an initial alignmen went through PRMI -> Check Fringes -> PRMI -> DRMI and then went all the way up to NLN.

                                                                                                                                          

Start Time System Name Location Lazer_Haz Task Time End
17:03 FAC Kim High Bay - Technical cleaning 19:03
18:55 VAC Gerardo FCES - Moving ion pumps 19:52
22:56 ISC Sheila, TJ LVEA Local Realign beatnotes 23:46
23:22 Tour Camilla & Parents LVEA & Roof N Just poping their heads in to see the IFO 23:42