TITLE: 05/30 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 124Mpc
SHIFT SUMMARY:
Lock#1:
Started off with an initial alignment after seeing some drifting on the OPLEVS, & OSEMS (esp. SR3 pitch, which seem to drift a large amount for only 4 hours). There doesn't appear to be a clear temperature correlation?
Both arms went through increase flashes, Yarm went smoothly and locked at a high 90%, Xarm struggled a bit and took more than twice as long, I tapped ETMX in pitch 0.3 microrads and it was enough for it to catch after it finished increase flashes and was still struggling on ENABLE_WFS. Good beatnotes, -4.5 (X) & -6 (Y).
SRM was badly aligned, after lots of SRM saturations and the ASC-AS_A signal was low (~2 instead of 4/5) I paused INIT_ALIGN and brought ALIGN_IFO to offload SR2 then I went to PREP_FOR_SRY and adjusted SRM mostly in pitch to make AS_AIR more symmetrical and to get higher highs, and lower lows on the H1:ASC-AS_A_DC_NSUM_OUT16 trace. I then unpaused INIT_ALIGN and rerequested SRC_ALIGN which went smoothly the 2nd try.
Lost it at FIND_IR, Yarm looked a little glitchy then it lost it
Lock#2:
Lost it at FIND_IR again, it seems like Yarm is killing it?
Lock#3:
Lost it at LOCKING_ALS, Yarm again I think
Lock#4:
COMM IR was found pretty easily, DIFF took a while, went through PRMI got it, took a little while for it to get DRMI despite good looking flashes.
Lockloss at MOVE_SPOTS 20:57, DCPD saturation right beforehand
Lock#5:
Couldn't get DRMI went through PRMI again, I had to tap PRM in pitch to catch, then in DRMI_1F I adjusted the BS in pitch
Had to stop at OMC_WHITENING for the violins to damp, IX12 & IY8 have changed phase, a negative gain damped IX12 down (-2, max of -4) instead of the +2 its set to in lscparams. IY8 also was rising, I changed its gain sign from 0.08 to -0.08 and it started to fall - Tagging SUS
Aquired NLN at 22:25UTC, we had to wait for ADS to converge for the CAMERA_SERVO as usual and some SEI SDF diffs to be checked
In Observing at 22:39UTC
DARM was glitching out a bit around 22:55 on the FOM
LOG:
Start Time | System | Name | Location | Lazer_Haz | Task | Time End |
---|---|---|---|---|---|---|
15:02 | FAC | Tyler+Sierra | CS | N | Infloor smoke detectors | 17:10 |
15:08 | FAC | Chris+Contractors | LVEA | N | Vinyl work | 18:46 |
15:09 | FAC | Kim | EndY | N | Technical Cleaning | 16:11 |
15:12 | FAC | Tyler+Johnson | EndY | N | FIre alarm testing | 16:09 |
15:21 | VAC | Jordan | EndX | N | Set up a pump, cp8 | 16:15 |
15:43 | VAC | Travis | EndX | N | Purge air compressor | 17:31 |
15:48 | FAC | APS | CS | N | Door access, FCES, High bay | 18:45 |
15:48 | EE | Fill | Ends | N | HEPI cabling, rack temps | 18:51 |
15:58 | CDS | Erik | CS | N | ADC card work, h1seih16 | 16:42 |
16:10 | FAC | Tyler+Johnson | OSB, Mids | N | Fire alarm tests | 22:00 |
16:12 | FAC | Kim | EndX | N | Quick checks, Garb check | 16:49 |
16:29 | FAC | Betsy | LVEA | N | Container checks, noise checks | 16:44 |
16:37 | CDS | Johnathan | MSR | N | DMT work | ?? |
16:00 | SEI | Jim | REMOTE | N | ISI BLND work | 17:22 |
16:50 | FAC | Kim | LVEA | N | Technical cleaning | 19:01 |
16:58 | VAC | Jordan, Gerardo | LVEA HAM5 | N | FTIR sample | 17:40 |
17:08 | FAC | Cindi | LVEA | N | Tech clean | 18:43 |
17:20 | FAC | Christina | OSB | N | Recycling items | 17:40 |
17:44 | VAC | Gerardo | Arms, Y2-8, X2-8 | N | Solar panel checks | 18:51 |
18:29 | FAC | Chris | LVEA | N | Check with vinyl crew, and pest traps | 19:01 |
18:32 | FAC | Betsy | LVEA | N | Sweep | 18:39 |
18:39 | VAC | Jordan | EndX | N | Turn off pump | 19:02 |
18:40 | FAC | Richard | LVEA | N | Check with APS | 18:46 |
20:15 | VAC | Jordan & Travis | MidX | N | Set up a pump | 20:35 |
21:00 | EE | Fill | MidY | N | Parts | 21:38 |