Reports until 16:00, Tuesday 30 May 2023
H1 General (SUS)
ryan.crouch@LIGO.ORG - posted 16:00, Tuesday 30 May 2023 (70003)
OPS Tuesday Day shift summary

TITLE: 05/30 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 124Mpc
SHIFT SUMMARY:

Lock#1:

Started off with an initial alignment after seeing some drifting on the OPLEVS, & OSEMS (esp. SR3 pitch, which seem to drift a large amount for only 4 hours). There doesn't appear to be a clear temperature correlation?

Both arms went through increase flashes, Yarm went smoothly and locked at a high 90%, Xarm struggled a bit and took more than twice as long, I tapped ETMX in pitch 0.3 microrads and it was enough for it to catch after it finished increase flashes and was still struggling on ENABLE_WFS. Good beatnotes, -4.5 (X) & -6 (Y).

SRM was badly aligned, after lots of SRM saturations and the ASC-AS_A signal was low (~2 instead of 4/5) I paused INIT_ALIGN and brought ALIGN_IFO to offload SR2 then I went to PREP_FOR_SRY and adjusted SRM mostly in pitch to make AS_AIR more symmetrical and to get higher highs, and lower lows on the H1:ASC-AS_A_DC_NSUM_OUT16 trace. I then unpaused INIT_ALIGN and rerequested SRC_ALIGN which went smoothly the 2nd try.

Lost it at FIND_IR, Yarm looked a little glitchy then it lost it

Lock#2:

Lost it at FIND_IR again, it seems like Yarm is killing it?

Lock#3:

Lost it at LOCKING_ALS, Yarm again I think

Lock#4:

COMM IR was found pretty easily, DIFF took a while, went through PRMI got it, took a little while for it to get DRMI despite good looking flashes.

Lockloss at MOVE_SPOTS 20:57, DCPD saturation right beforehand

Lock#5:

Couldn't get DRMI went through PRMI again, I had to tap PRM in pitch to catch, then in DRMI_1F I adjusted the BS in pitch

Had to stop at OMC_WHITENING for the violins to damp, IX12 & IY8 have changed phase, a negative gain damped IX12 down (-2, max of -4) instead of the +2 its set to in lscparams. IY8 also was rising, I changed its gain sign from 0.08 to -0.08 and it started to fall - Tagging SUS

Aquired NLN at 22:25UTC, we had to wait for ADS to converge for the CAMERA_SERVO as usual and some SEI SDF diffs to be checked

In Observing at 22:39UTC

DARM was glitching out a bit around 22:55 on the FOM

LOG:                                                                                                                           

Start Time System Name Location Lazer_Haz Task Time End
15:02 FAC Tyler+Sierra CS N Infloor smoke detectors 17:10
15:08 FAC Chris+Contractors LVEA N Vinyl work 18:46
15:09 FAC Kim EndY N Technical Cleaning 16:11
15:12 FAC Tyler+Johnson EndY N FIre alarm testing 16:09
15:21 VAC Jordan EndX N Set up a pump, cp8 16:15
15:43 VAC Travis EndX N Purge air compressor 17:31
15:48 FAC APS CS N Door access, FCES, High bay 18:45
15:48 EE Fill Ends N HEPI cabling, rack temps 18:51
15:58 CDS Erik CS N ADC card work, h1seih16 16:42
16:10 FAC Tyler+Johnson OSB, Mids N Fire alarm tests 22:00
16:12 FAC Kim EndX N Quick checks, Garb check 16:49
16:29 FAC Betsy LVEA N Container checks, noise checks 16:44
16:37 CDS Johnathan MSR N DMT work ??
16:00 SEI Jim REMOTE N ISI BLND work 17:22
16:50 FAC Kim LVEA N Technical cleaning 19:01
16:58 VAC Jordan, Gerardo LVEA HAM5 N FTIR sample 17:40
17:08 FAC Cindi LVEA N Tech clean 18:43
17:20 FAC Christina OSB N Recycling items 17:40
17:44 VAC Gerardo Arms, Y2-8, X2-8 N Solar panel checks 18:51
18:29 FAC Chris LVEA N Check with vinyl crew, and pest traps 19:01
18:32 FAC Betsy LVEA N Sweep 18:39
18:39 VAC Jordan EndX N Turn off pump 19:02
18:40 FAC Richard LVEA N Check with APS 18:46
20:15 VAC Jordan & Travis MidX N Set up a pump 20:35
21:00 EE Fill MidY N Parts 21:38
Images attached to this report