Displaying report 1-1 of 1.
Reports until 09:40, Tuesday 30 May 2023
H1 CDS
david.barker@LIGO.ORG - posted 09:40, Tuesday 30 May 2023 - last comment - 10:34, Tuesday 30 May 2023(70002)
h1seih16 powered down for ADC error investigation

WP11227

Jim, Erik, Fil, EJ, Dave:

h1seih16 is currently powered down. Erik has found a possible issue with the second Adnaco backplane in the IO Chassis, he is in the process of moving all the cards from the 2nd to the 3rd Adnaco backplanes.

EJ confirmed that a communication issue with the second backplane (which holds A1, A2, A3 and D1) would raise an timing error on A1 but not the other cards.

Comments related to this report
erik.vonreis@LIGO.ORG - 10:34, Tuesday 30 May 2023 (70004)

1 DAC and 3 ADCs were moved from adnaco PCIe expansion board 2 to board 3.  h1seih16 was powered back up and is running.  Board 2 appears to be working again with no IO cards plugged into it.

Displaying report 1-1 of 1.