Reports until 04:21, Tuesday 06 June 2023
H1 ISC
camilla.compton@LIGO.ORG - posted 04:21, Tuesday 06 June 2023 - last comment - 10:01, Tuesday 06 June 2023(70169)
OPS Owl Mid Shift Update

STATE of H1: Lock Acquisition

Lost lock at 09:37UTC, cause was 11Hz PRCL instability, see attached and Brina's 70153. this is with Jenne's updated PRCL2 gain of 1.7 70160. Note there is an issue with the lockloss tool but you can use the command line tool with 'lockloss show 1370079438' to get the ndscope plots.

Successfully did an initial alignment after couldn't lock PRMI (with moving PRM) and we lost lock at CHECK_MICH_FRINGES. Since then locking has been fine, currently at MAX_POWER.

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 10:01, Tuesday 06 June 2023 (70182)

I'm hopeful (although have not yet looked closely at the lockloss) that this was more due to the earthquake than the PRCL gain.  I note that the amplitude of the 11 Hz in this plot is ~10x lower than those in Brina's alog.  For now I've set the guardian to put the PRCL2 gain to 1.7, and we'll see if we get another nice long lock like this one was.