Ops Day Shift Summary

TITLE: 06/06 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Preventive Maintenance
SHIFT SUMMARY: Maintenance day. During maintenance there was a temperature excursion in the LVEA and end stations moving temperatures by just over a degree F (alog70194). This was enough for our alignment to be too far off to lock. The main symptoms were ALS COMM beatnotes very low and ALS Y not able to lock or get decent flashes, and the ALS camera images more clipped than usual. Moving PR3 would be temporarily helpful, but as the temperatures were moving back, the alignment would change again. Temps returned a few hours ago, but the suspensions aren't back yet. PR3 Yaw started the day at 153.5, it is now at 154.6 but we have made it past DC readout and are powering up.

At the next lock loss, it would probably be good to see if moving PR3 back in the direction of the 153.5 would be beneficial as the suspensions get back to their previous positions. Go to a green arms locking state and if cameras look clipped, buildups are poor even though alignment seems as best you can get, and beatnotes are bad (assuming you can get the arms locked), then move PR3 and see if these issues improve.
LOG:

Start Time System Name Location Lazer_Haz Task Time End
13:21 CDS Erik Remote n Rebooting work stations 13:21
14:17 COMM Camilla CR n PRCL OLG Measurement 14:27
14:31 PEM PEM_MAG_INJ GRD Auto n Automatic magnetic injections 14:46
14:46 SUS SUS_CHARGE GRD Auto n Automatic in-lock charge measurements 15:01
15:00 FAC Karen EY n Technical Cleaning 16:31
15:02 SUS Kim EX n Technical Cleaning 16:25
15:05 SEI Jim, Randy EY n HEPI skid hole drilling 16:49
15:08 VAC Jordan LVEA n Turbo pump checks 19:08
15:14 OpLev Jeff, Jason CR n PR3, SR3 oplev calibration 18:58
15:16 FAC Cindi FCES n Tech clean 16:23
15:16 VAC Gerardo LVEA n LY rack door install 16:38
15:26 FAC Chris, pest control LVEA, outbuilds n Pest sweeps 17:56
16:09 VAC Janos EX n Dewar jacket pumping ongoing
16:09 VAC Janos LEVA n Check on turbos 18:09
16:10 FAC Tyler, Johnston co OSB n Fire alarm testing 16:27
16:13 - Betsy, guest LVEA n Tour 16:54
16:16 SEI Jim FCES n HAM8 feed through protection 18:10
16:32 FAC Kim, Cindi, Karen LVEA n Tech clean 18:32
16:40 VAC Richard LVEA n Regulator hunt 18:33
16:46 SQZ Vicky LVEA - Ebay LOCAL SQZ table alignment in local hazard 18:38
16:51 FAC Tyler, Fire marshal, Johnston co EY, EX n Fire system testing 18:51
17:02 SEI Jim, Fil, Randy, Patrick EX n HEPI beckhoff 18:44
17:09 CDS Jonathan MSR n Cold spare router addition to rack 19:09
18:11 EPO Cassidy LVEA n Gate valve pictures 18:53
18:21 - Eadie Yarm n Run 18:58
18:34 FAC Ken OSB to LSB n Move lift 18:50