Notes from briefly trying some different gen sqz levels today

Jenne, Vicky. We took ~1 hour for sqz commissioning, from hours ~1-2 of lock.

Overall change is increasing the generated SQZ level from 12dB (60uW, last lock) to 14dB starting this lock (75uW). I don't think sqz is soley responsible for the lower range this evening (possibly some extra no-sqz noise). And, it feels like trends in the SQZ BLRMS are dominated by drifts of the technical noise and SRCL detuning over thermalization, so there isn't a clear correlation of more sqz = more range or better blrms. So while I do think more sqz is better, I think right now this test was probably limited by the elevated + drifting technical noise in the ifo, so I backed off the sqzing. Maybe with a thermalized IFO with stable technical noise, we'd see clearer trends of total noise vs. injected squeezing. Some notes from today: