Displaying report 1-1 of 1.
Reports until 11:59, Thursday 08 June 2023
H1 DAQ
david.barker@LIGO.ORG - posted 11:59, Thursday 08 June 2023 (70283)
offload of raw minute trend files from h1daqtw0 to h1daqframes-0 complete

WP11245

Jonathan, TJ, Dave:

The offload of the past 6 months' of raw minute trend files from h1daqtw0 SSD-RAID to h1daqframes-0 HDD-RAID is complete.

The copy took from Tue 11:08 - Wed 12:28 = 25hrs 20min

This morning I reconfigured nds0 to serve these data from their permanent archive location and restarted the nds.

The deletion of the old files from tw0 SSD was from 09:06 to 11:15 this morning, it took 2hrs 9 min

I'm keeping WP11245 open since the reconfiguration of h1daqnds0's daqdrc has only been done so far via manual edits, next Tuesday Jonathan will add this to the DAQ puppet.

Thu08Jun2023
LOC TIME HOSTNAME     MODEL/REBOOT
08:41:24 h1daqnds0    [DAQ]
 

Displaying report 1-1 of 1.