Displaying report 1-1 of 1.
Reports until 13:39, Tuesday 13 June 2023
H1 CDS
david.barker@LIGO.ORG - posted 13:39, Tuesday 13 June 2023 - last comment - 14:21, Tuesday 13 June 2023(70419)
CDS Maintenance Summary: Tuesday 13th June 2023

WP11256 Upgrade EY HEPI Pump Controller to Beckhoff

Patrick, Fil, Jim, Dave:

Patrick and Fil installed the new Beckhoff HEPI Pump Controller at EY alongside the original "Ben purple box". The new unit has the temporary name h1hpipumpctrley1, Fil ran a new ethernet cable to it from sw-ey-aux port14.

Patrick and Fil got the new unit booted and on the network. Its EPICS IOC is running, there is no overlap in channel names between the old and the new EPICS databases, so they can run at the same time.

The new unit was not put into production today, we are still using the original unit to control EY pumps.

WP11245 TW0 raw minute trend files offload

Jonathan, Dave:

To complete last week's offload of raw minute trend files from TW0 SSD to h1daqframes-0 HDD, the hand edited daqdrc on h1daqnds0 was put into puppet by Jonathan. We verified the configuration when the DAQ was restarted today.

WP11254 Atomic Clock Re-synchronize with timing system

Daniel:

Daniel resync'ed the atomic clock. Please see his alog for details.

WP11257 Remove obsolete filter-modules-with-control parts from h1als[ex,ey]

Daniel, Dave:

Daniel downgraded the H1:LSC-X_ARM_DRIVE and H1:LSC-Y_ARM_DRIVE filter modules on h1als[ex,ey] to standard filter modules. This fixes the issue of the fm-w-ctrl having hardcoded Cin and Cmask attempting to turn on non-existent FM3 and FM5 filters.

Because the MASK PV for these FMs were removed from the INI files, a DAQ restart was required.

DAQ Restart

Dave, Jonathan:

The DAQ was restarted for the above h1als[ex,ey] model changes. Both GDS0 and GDS1 required a second restart to sync their channels lists, other than that it was a good restart and the DAQ configuration is consistently in puppet.

Comments related to this report
david.barker@LIGO.ORG - 13:50, Tuesday 13 June 2023 (70420)

Tue13Jun2023
LOC TIME HOSTNAME     MODEL/REBOOT
12:31:30 h1iscex      h1alsex     
12:32:00 h1iscey      h1alsey     


12:33:45 h1daqdc0     [DAQ] 0-leg
12:33:55 h1daqfw0     [DAQ]
12:33:55 h1daqtw0     [DAQ]
12:33:56 h1daqnds0    [DAQ]
12:34:03 h1daqgds0    [DAQ]
12:35:11 h1daqgds0    [DAQ] gds0 2nd restart


12:36:53 h1daqdc1     [DAQ] 1-leg
12:37:02 h1daqfw1     [DAQ]
12:37:03 h1daqnds1    [DAQ]
12:37:03 h1daqtw1     [DAQ]
12:37:11 h1daqgds1    [DAQ]
12:38:06 h1daqgds1    [DAQ] gds1 2nd restart
 

david.barker@LIGO.ORG - 14:21, Tuesday 13 June 2023 (70422)

DAQ Frame File Channel List Change

Two slow channels removed from the DAQ Frame today (name, size-bytes, data-rate-Hz)

H1:LSC-X_ARM_DRIVE_MASK 4 16

H1:LSC-Y_ARM_DRIVE_MASK 4 16
 

Displaying report 1-1 of 1.