WP11256 Upgrade EY HEPI Pump Controller to Beckhoff
Patrick, Fil, Jim, Dave:
Patrick and Fil installed the new Beckhoff HEPI Pump Controller at EY alongside the original "Ben purple box". The new unit has the temporary name h1hpipumpctrley1, Fil ran a new ethernet cable to it from sw-ey-aux port14.
Patrick and Fil got the new unit booted and on the network. Its EPICS IOC is running, there is no overlap in channel names between the old and the new EPICS databases, so they can run at the same time.
The new unit was not put into production today, we are still using the original unit to control EY pumps.
WP11245 TW0 raw minute trend files offload
Jonathan, Dave:
To complete last week's offload of raw minute trend files from TW0 SSD to h1daqframes-0 HDD, the hand edited daqdrc on h1daqnds0 was put into puppet by Jonathan. We verified the configuration when the DAQ was restarted today.
WP11254 Atomic Clock Re-synchronize with timing system
Daniel:
Daniel resync'ed the atomic clock. Please see his alog for details.
WP11257 Remove obsolete filter-modules-with-control parts from h1als[ex,ey]
Daniel, Dave:
Daniel downgraded the H1:LSC-X_ARM_DRIVE and H1:LSC-Y_ARM_DRIVE filter modules on h1als[ex,ey] to standard filter modules. This fixes the issue of the fm-w-ctrl having hardcoded Cin and Cmask attempting to turn on non-existent FM3 and FM5 filters.
Because the MASK PV for these FMs were removed from the INI files, a DAQ restart was required.
DAQ Restart
Dave, Jonathan:
The DAQ was restarted for the above h1als[ex,ey] model changes. Both GDS0 and GDS1 required a second restart to sync their channels lists, other than that it was a good restart and the DAQ configuration is consistently in puppet.
Tue13Jun2023
LOC TIME HOSTNAME MODEL/REBOOT
12:31:30 h1iscex h1alsex
12:32:00 h1iscey h1alsey
12:33:45 h1daqdc0 [DAQ] 0-leg
12:33:55 h1daqfw0 [DAQ]
12:33:55 h1daqtw0 [DAQ]
12:33:56 h1daqnds0 [DAQ]
12:34:03 h1daqgds0 [DAQ]
12:35:11 h1daqgds0 [DAQ] gds0 2nd restart
12:36:53 h1daqdc1 [DAQ] 1-leg
12:37:02 h1daqfw1 [DAQ]
12:37:03 h1daqnds1 [DAQ]
12:37:03 h1daqtw1 [DAQ]
12:37:11 h1daqgds1 [DAQ]
12:38:06 h1daqgds1 [DAQ] gds1 2nd restart
DAQ Frame File Channel List Change
Two slow channels removed from the DAQ Frame today (name, size-bytes, data-rate-Hz)
H1:LSC-X_ARM_DRIVE_MASK 4 16