(Alexa, Daniel, Stefan) We - debugged the shutter software, and got it to work - switched the shutter control cables between shutter control 2 and 3 - set up the appropriate threshold for the shutter (0V) - placed an iris in the main beam path to guarantee that the shutter protects the RFPD - verified the safety of the RFPD by moving PRM, and measuring the max power out of the RFPD. - aligned the RFPD to the weak ITMY reflected beam (with the PRM misaligned) - switched the supply cables between POPAIR_A and REFLAIR_A (they are now going to the right input) - verified that we see fringes on the DC readback - turned on the REFLAIR_A_RF9_LF power supply, verified that all whitening is 0 - verified that we get a signal in H1:LSC-REFLAIR_A_LF_OUT - moved the RF cable to the REFLAIR demodulation board (i.e. the signal currently does not go to the real common mode board) - verified that we have a signal in H1:LSC-REFLAIR_A_RF9_I_OUT - verified that its whitening is all off - tried to lock the arm cavity, but had excessive pitch motion PS: - The RefCav is still pretty lame in re-locking