Displaying report 1-1 of 1.
Reports until 14:51, Wednesday 14 June 2023
H1 ISC
camilla.compton@LIGO.ORG - posted 14:51, Wednesday 14 June 2023 - last comment - 17:23, Wednesday 14 June 2023(70451)
Ran PRCL OLG Measurement at 21:37UTC

Last done in alog 70160. Measurement taken after 2h35 in NLN.

Magnitude is 1 at 26.5Hz and 26.5degrees. Plot attached.

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 17:06, Wednesday 14 June 2023 (70462)

Here is a plot showing the PRCL gain thermalization (same as from alog 70211), but with information from Camilla's measurement today added in the small grey marker at about 155 mins.  It needs to be high relative to what we'd been using (pink line) since June 6th.  Recall that these PRCL locklosses we've been having are likely because our PRCL gain is too low.  So, I'll see if I can make another thermalization curve that increases faster.

Images attached to this comment
jenne.driggers@LIGO.ORG - 17:23, Wednesday 14 June 2023 (70463)

I've got a new candidate thermalization, the yellow curve in this (becoming much too busy) plot.  This won't quite get the gain as high as it wants at the 2hr35min point, but it also won't overshoot the 4 hour target from 6 June 2023 by too much.  The thermalization guardian just holds the gain at the value at the end of this plot (it doesn't keep following the curve forever), so the final gain won't be very different with this new candidate (yellow) versus what we've been running with after 6 hours of lock in pink.

I'm going to implement this quickly before we get relocked.  This means using a GAIN_SCALE of 5.25 (has been 5.55 for pink trace) and a TIME_CONSTANT of 5571 (has been 7800 for blue, orange, pink, green traces). 

I modified and loaded the THERMALIZATION guardian, and checked it in to the svn, while we were relocking.  Hopefully this will reduce the number of PRCL locklosses we're seeing.

Images attached to this comment
Displaying report 1-1 of 1.