Ran Two PRCL OLG Measurements

Jenne had me run a couple of PRCL OLG measurements this evening.  Referencing Camilla's measurement from alog #70451.

Measurement #1 ~00:49utc

The first measurement was done as soon as we were at NOMINAL LOW NOISE (had to wait a few min for the Camera Servo node to complete) at 0049utc.  Magnitude is 1 at 32.0Hz with phase of 24.1 deg.

(see attached 1st plot & file is at /ligo/home/corey.gray/dtt/prcl_olg_noise_full_lock_nln_0049_15062023.xml)

Measurement #2 ~01:19 utc

Second measurement was run after Robert performed PEM measurments.  Magnitude is 1 at 35.0 Hz with phase of 25.1 deg.

(see attached 2nd plot & file is at /ligo/home/corey.gray/dtt/prcl_olg_noise_full_lock_nln_0119_15062023.xml)