OPS Day Shift Summary

TITLE: 06/15 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 135Mpc
SHIFT SUMMARY: Large EQ today kept us DOWN for ~ 4 hours. EX has been left in LASER HAZARD for Robert's photos he plans to take in a commissioning time later. Plan for commissioning time at 23:25UTC.
LOG:

Start Time System Name Location Lazer_Haz Task Time End
15:10 CDS Dave Remote N Rebooting nuc26, nuc30 and cameras with issues 15:33
15:54 CDS WAP Remote N Dave turned MSR WAP on/off 70480 15:56
17:08 PEM Plane CR N Plane heard overhead (tagging DetChar) 17:10
17:15 VAC Janos MY N VAC checks 17:50
18:33 PEM Robert EX YES Installing cameras at EX WP#11264 19:59
18:43 WAP Robert EX N Wifi turned ON 22:40
19:52 CDS Erik, Jonathan CER N Check on HAM6 camera cable 70478 20:00
20:00 LASER EX EX YES EX Left in LASER HAZARD 04:00
Images attached to this report