TITLE: 06/15 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 136Mpc
SHIFT SUMMARY:
H1 locked at NLN the entire shift. There were a little over 2hrs OUT of OBSERVING for COMMISSIONING work by Robert & Elenna. H1 rode through a 4.5 earthquake from Mexico. HAM6 OMC video is not working on nuc30 (I believe Erik has been made aware.).
LOG:
- 2320 nuc30's DARM fom died (it also disappeared yesterday in the early evening).
- 2325-0148 imaging work at EX (Robert for ~2hrs)
- 0003 EX wifi turned on (corey)
- 2334 Checking VAC pump at MY (janos)
- 2336-0143 out of OBSERVING for COMMISSIONING time (~2hrs)
- 2338-0028 ISC measurement in parallel w/robert (elenna)
- 1800-1830 MY run (camilla)
- 0224 EARTHQUAKE: SRM verbal alarm (which is also on tidal scope on nuc28); noticed oscillations on all ASC signals on nuc29---possibly 4.5 Oaxca EQ
- 0226 (1) yellow picket fence
- 0227 EQ Mode activated automatically
- 0245 MINOR dust alarm in the Optics Lab
- 0256 MAJOR alarm....but died down on its own.
- 0530-0547 Filled TCS chillers (corey)