corey.gray@LIGO.ORG - posted 17:18, Friday 16 June 2023 - last comment - 18:33, Friday 16 June 2023(70535)
H1 Lockloss

(Corey, Elenna)

With our short OBSERVING stretch (6-min) ending due to a ringing-up (over 90-sec) ASC MICH_P (see attached), Elenna and I decided to back out her HAM ASC FF change for this recent lock. 

Elenna's change was:

We have now reverted from this new FM4 to the original FM3 ("FFX0423").

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 18:33, Friday 16 June 2023 (70537)SEI

For this current lock, the HAM1 ASC FF changes have been reverted and here is the SDF ACCEPTING of the original filters.