SLC - Manifold Cryopump assembly and installation
Thursday, 11 July 2013

Gerardo Moreno, Scott Shankle, Mike Vargas, Nichole Washington

Weldments and Cylinder were unwrapped and brought into the cleanroom with the help of Apollo.

Weldments were assembled to Cylinder. 
Assembly was difficult because the holes are to small, no room for adjustment of parts. Hole diameter on Weldments and Cylinder is 0.209". Screw diameter is 0.190". All 35 locations were mated. 
Holes should be reamed out for future assemblies.

pics 1 and 2 - teamwork
pic 3 - buttoning up
pic 4 - end of the day

Time spent on actual assembly for the day was ~4 hours.