Displaying report 1-1 of 1.
Reports until 05:54, Wednesday 21 June 2023
H1 General (TCS)
anthony.sanchez@LIGO.ORG - posted 05:54, Wednesday 21 June 2023 - last comment - 08:46, Wednesday 21 June 2023(70644)
Lockloss Wednesday Owl shift


11:22 UTC Lockloss 22 minutes after turning the ring heaters down.
https://ldas-jobs.ligo-wa.caltech.edu/~lockloss/index.cgi?event=1371381773

While referencing alog 70616 I changed
H1:TCS-ETMX_RH_SETUPPERPOWER
H1:TCS-ETMX_RH_SETLOWERPOWER
&&
H1:TCS-ETMY_RH_SETUPPERPOWER
H1:TCS-ETMY_RH_SETLOWERPOWER

all to 1W from 1.2W. Change made at 11:00 UTC.
Changes accepted in SDF at 11:02 UTC.

Comments related to this report
jeffrey.kissel@LIGO.ORG - 08:46, Wednesday 21 June 2023 (70657)CAL
Tagging CAL, as we expect a cavity pole change from this ring heater change.
Displaying report 1-1 of 1.