Reports until 12:14, Wednesday 21 June 2023
H1 CAL
camilla.compton@LIGO.ORG - posted 12:14, Wednesday 21 June 2023 - last comment - 12:55, Wednesday 21 June 2023(70671)
Sensing Function Calibration Measurements started at 19:10UTC

Following TakingCalibrationMeasurements wiki for only sensing function measurements. Jeff also turned off Low frequency calibration lines (been on for this lock) using the guardian CAL_AWG_LINES.

State of the IFO medm just before these started attached.

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 12:55, Wednesday 21 June 2023 (70674)

Although we were only in NLN for 2 hours when these measurements started, the IFO has been at 60W input for 3h20 minutes, see plot attached.

Calibration report is in /ligo/groups/cal/H1/reports/20230621T191615Z/H1_calibration_report_20230621T191615Z.pdf and attached.

Images attached to this comment
Non-image files attached to this comment