Coherences for 60W lock

Coherence from last night lock at 60W, with the correct 2.1 gain for the SRCL FF:

https://ldas-jobs.ligo-wa.caltech.edu/~gabriele.vajente/bruco_GDS_1371427218/

Images attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 13:28, Thursday 22 June 2023 (70731)

With the improvement of HAM1 FF and the ITMY A2L gains (70730, 70727), there is a reduction in CHARD and DHARD coherence. The attached plot shows the coherences after these changes. I think this indicates that these changes were good, and we can probably claim we are not limited (much) by ASC noise right now. The biggest contender for coherence is DHARD Y, but that is mostly below 10 Hz. We would probably also improve the coupling of CSOFT P slightly by dropping the gain back to 20 (discussed and agreed in commissioning meeting).

Images attached to this comment
gabriele.vajente@LIGO.ORG - 09:00, Thursday 22 June 2023 (70717)

Here's how much could be ganed with MICH and SRCL subtraction (or better tuned FF) and with jitter subtraction

Images attached to this comment